Portable Energy Meter Testing Equipment YC99T Series


Product Description



The product is used in a variety of professional settings, including measurement testing centres of grid companies, measurement departments of power supply companies and power plants, national measurement testing institutions and metrology inspection departments, measurement testing departments of medium-sized enterprises such as railway and petrochemical companies. Additionally, it is utilised by manufacturers of energy meters, encompassing their production, research and development, and testing departments, as well as in academic institutions and associated research bodies.



Simple Description



This product is used in a variety of professional settings, including measurement testing centres of grid companies, measurement departments of power supply companies and power plants, national measurement testing institutions and metrology inspection departments, measurement testing departments of medium-sized enterprises such as railway and petrochemical companies. It is also used by manufacturers of energy meters, including their production, research and development, and testing departments, as well as in universities and related research institutions, and specialised laboratories.

The meters user can calibrate the following meters: single-phase active energy meter, three-phase three-wire active energy meter, three-phase three-wire composite meter, three-phase four-wire active energy meter, three-phase four-wire composite meter, three-phase three-wire sine reactive energy meter, three-phase four-wire sine reactive energy meter, two elements 60° reactive energy meter, two elements 90° reactive energy meter, and three elements 90° reactive energy meter.


Specifications




Model No.

YC99T-3C

Meter Position / Accuracy

3 / 0.05

AC Voltage output

Range

57.7V,100V, 220V, 380V 660

Adjustment Range

(0-120)%RG (RG is Range)

Adjust Resolution

0.01%RG, 0.1%RG, 1%RG, 10%RG

Stability

0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)

Distortion

0.2% (Non capacitive load)

Max Output load

20VA/phase

Measurement Accuracy

%0.05%RG(0.05cl), %0.1%RG(0.1cl)

AC Current output

Range

0.05A 0.2A 1A 5A 16.67A 50A

Adjust Range

(0-120)%RG (RG is Range)

Adjust Resolution

0.01%RG, 0.1%RG, 1%RG, 10%RG

Stability

0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)

Distortion

0.2% (Non capacitive load)

Max Output load

50VA(50A range)

Measurement Accuracy

%0.05%RG(0.05cl), %0.1%RG(0.1cl)

Power output

Stability

0.01%/2min(0.05cl), 0.02%/2min(0.1cl)

Active, Reactive power accuracy

%0.05%RG

Phase output

Output adjusting range

0 ~ 359.99

Output adjusting power

10°,1°,0.1°,0.01°optional

Resolution

0.01

Measurement accuracy

%0.05

Power factor output

Adjusting range

-1~0~+1

Measuring resolution

0.0001

Measurement accuracy

%0.0005

Frequency output

Adjusting range

40Hz – 70Hz

Output adjusting resolution

1Hz, 0.1Hz, 0.01Hz, 0.001Hz optional

Resolution

0.001Hz

Accuracy

%0.002Hz

Harmonic setting

Harmonic order

2nd~63rd

Harmonic amplitude

0~40%

Harmonic angle

0 ~359.00

Harmonic set error

2nd ~ 31st : %0.1%, 32nd~63rd: %0.2%

Energy error measurement

Active energy basic error limit

%0.05%RD(voltage30V~660V,current0.02A~60A,PF 0.5)

Reactive energy basic error limit

%0.1%RD(voltage30V~660V,current0.02A~60A,PF 0.5)

Standard crystal

Frequency accuracy

%0.5ppm (leave factory@25 )

Frequency stability

%0.1ppm,-20 ~+70

Energy pulse input

Number of energy pulse input

3 channels active, 3 channels reactive

General parameters

Power supply

AC220V%15% or 110V%15%

Frequency

50Hz~60Hz

Consumption

60VA~1000VA

Environment condition

20 ~ 30 relative humidity

Storage environment

-20 ~50

Size & Weight

600mm(L) 400mm(W) 266mm(H), 30kg



Model No.

YC99T-5C

Meter Position / Accuracy

3 / 0.05cl

AC Voltage output

Range

57.7V,100V, 220V, 380V

Adjustment Range

(0-120)%RG (RG is Range)

Adjust Resolution

0.01%RG, 0.1%RG, 1%RG, 10%RG

Stability

0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)

Distortion

0.2% (resistance load)

Max Output load

20VA/phase

Measurement Accuracy

%0.05%RG(0.05cl), %0.1%RG(0.1cl)

AC Current output

Range

0.05A 0.2A 1A 5A 20A 100A

Adjust Range

(0-120)%RG (RG is Range)

Adjust Resolution

0.01%RG, 0.1%RG, 1%RG, 10%RG(optional)

Stability

0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)

Distortion

0.2% (Non capacitive load)

Max Output load

100VA(100A range)

Measurement Accuracy

%0.05%RG(0.05cl), %0.1%RG(0.1cl)

Power output

Stability

0.01%/2min(0.05cl), 0.02%/2min(0.1cl)

Active, Reactive power accuracy

%0.05%RG

Phase output

Output adjusting range

0 ~ 359.99

Output adjusting power

10°,1°,0.1°,0.01°optional

Resolution

0.01

Measurement accuracy

%0.05

Power factor output

Adjusting range

-1~0~+1

Measuring resolution

0.0001

Measurement accuracy

%0.0005

Frequency output

Adjusting range

45Hz – 70Hz

Output adjusting resolution

1Hz, 0.1Hz, 0.01Hz, 0.001Hz

Resolution

0.001Hz

Accuracy

%0.002Hz

Harmonic setting

Harmonic order

2nd~63rd

Harmonic amplitude

0~40%

Harmonic angle

0 ~359.99

Harmonic set error

2nd ~ 31st : %0.1%, 32nd~63rd: %0.2%

Energy error measurement

Active energy basic error limit

%0.05%RD(voltage30V~380V,current0.02A~120A,PF 0.5)

Reactive energy basic error limit

%0.1%RD(voltage30V~380V,current0.02A~120A,PF 0.5)

Standard crystal

Frequency accuracy

%0.5ppm (leave factory@25 )

Frequency stability

%0.1ppm,-20 ~+70

Energy pulse input

Number of energy pulse input

3 channels active, 3 channels reactive

General parameters

Power supply

AC220V%15% or 110V%15%

Frequency

50Hz~60Hz

Consumption

60VA~1000VA

Environment condition

20 ~ 30 relative humidity

Storage environment

-20 ~50

Size & Weight

600mm(L) 400mm(W) 266mm(H), 48kg


Portable Energy Meter Testing Equipment YC99T Series


Portable Energy Meter Testing Equipment YC99T Series

Inquiry Cart 0