Add to Cart
1. Measures mechanical, electronic mechanical, and electronic meters (automatic, semi-automatic, manual).
2. Meters: 3P4W, 3P3W, 1P2W.
3. Modes: active, reactive, cross-connected reactive power.
4. Simultaneous measurement of same-spec meters with different constants.
5. Automatic rotor mark positioning for mechanical meters.
6. Starting and creeping tests.
7. Protection against overload, short circuit, open circuit.
8. Lightweight, strong, corrosion-resistant aluminum alloy.
9. Windows-compatible software (2000/XP/7/8/10) with modules for error, harmonic, demand, and influence tests.
1. High-quality product
2. Over 18 months warranty
3. Highest accuracy class: 0.01/0.02
4. Extremely high power stability
5. Timing error test
6. Influence tests (voltage, frequency, harmonics)
7. RS232 and Ethernet ports in each meter position
Technical Speciation | |
Max Number Of Meter Positions | 6 |
Accuracy Class | 0.01% / 0.02% |
Power Source | YCS-103-X |
Standard Meter | ZERA: COM3003 RADIAN: RD33-233 EMH/MTE: K2006 GENY: SZ03A-K8 |
Scanning Head | YCG-S Series |
Voltage | |
Test voltage output(Phase-Neutral) | 3x(40V~500V)(or customized) |
Power of the voltage output | 3x200VA |
Resolution | Better than 0.001% of full scale value of range |
Stability | Better than 0.002% /h (integration time 150s) |
Load regulation from 0~max. load | Better than 0.01% |
Distortion factor | Better than 0.05% for linear resistance load |
Harmonic | 2nd~21st free programmable |
Current | |
Test current output | 3x (1mA~120A) max. to 230A |
Power of the current output | 3x300VA |
Resolution | Better than 0.001% of full scale value of range |
Stability | Better than 0.002% /h (integration time 150s) |
Load regulation from 0~max. load | Better than 0.01% |
Distortion factor | Better than 0.05% for linear resistance load |
Harmonic | 2nd~21st free programmable |
Phase angle | |
Range | 0~360⁰ |
Resolution | 0.01⁰ |
Frequency | |
Range | 45Hz~65Hz |
Resolution | 0.001Hz |
Error display | |
Type of error display | Red LED |
Resolution of error displays | 8 digitals |
Other | |
Voltage supply | 3x220/380V±10%(or customized) 50/60Hz ±2Hz |
Ambient temperature | -10°C~+40°C |
Relative humidity | 35%~85% |
For more information, please visit our official website:http://www.genymetertestequipment.com/