Brand Name :GENY
Model Number :YC1893D
Certification :ISO, CE
Place of Origin :CHINA
MOQ :1 Piece
Payment Terms :L/C,T/T,D/P
Supply Ability :100/Year
Model NO. :YC1893D
Test voltage output(Phase-Neutral) :3x(24V-300V)(or customized)
Harmonics :2nd-41st free programmable
Setting accuracy :Better than 0.05% at the final range value
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

High-Performance Calibration Equipment for Three-Phase Electricity Meters

General Introduction


YC-1893D is high-performance calibration equipment for three-phase electricity meters, which combines characteristics of different users in different fields including power supply, metrology and manufacturer of electricity meters. It is designed and manufactured in compliance with IEC60736 to meet various requirements in calibration of electricity meters today and the future.


Convenient Verifying Features:



 Clear high-brightness LED error display
 Wide range current output setting
 Both manual/automatic positioning of the color mark on the plate of the verified meter.
 Centralized overturn of the multi-position scanning head
 Fast and convenient wiring method
 Suit for mechanical meter or electronic meter
 Reliable and stable power source

Flexible system characteristics:


 RS-232 and RS-485 standard interfaces
 Automatic verification by PC
 Manual verification by keyboard
 Simultaneous verification of different constant meters
 Flexible setting of the verification projects
 Software options for multi-constant standard electric energy meters
 Barcode input and network access functions


Product Parameters


Application Conditions and Requirements
Environment Power Requirement Safety
Operation Humidity Altitude Voltage Supply IP Class Conformity
Temperature
-10ºC--+40ºC 0.5 <2500m 3x220/380V±10%(or customized) IP30 CE conform
50/60Hz±2Hz


Type YC1893D-6 YC1893D-12 YC1893D-24 YC1893D-48
Number of meter positions 6 12 24 48
Accuracy 0.05
Power Source YCS-103-250 YCS-103-600 YCS-103-1200 YCS-103-2500
Reference Standard Meter SZ-03A-K8
Scanning Head YCG-2-series
Voltage
Test voltage output(Phase-Neutral) 3x(24V-300V)(or customized)
Power of the voltage output Max.3x100VA Max.3x250VA Max.3x500VA Max.3x1000VA
Resolution Better than 0.01%of full scale value of range
Setting accuracy Better than 0.05%at the final range value
Stability Better than 0.005%/h(integration time 150 s)
Load regulation from 0-max.load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonics 2nd-41st free programmable
Current
Test current output 3x(1mA-120A/200A)
Power of the current output Max.3x250VA Max.3x500VA Max.3x1000VA Max.3x2000VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005%/h(integration time 150 s)
Load regulation from 0-max.load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonics 2nd-41st free programmable
Phase angle
Range 0-360°
Resolution 0.01°
Setting accuracy 0.1°
Frequency
Range 45Hz-65Hz
Resolution 0.01Hz
Error display
Type of error display Red LED
Resolution of the error displays 8 digits