Add to Cart
YCS—103
YCS-101
Parameter | YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 |
Voltage | ||||
Test Voltage Output (Phase-Neutral) | 3×(24V – 288V) or customized | 3×(24V – 288V) or customized | 3×(24V – 288V) or customized | 3×(24V – 288V) or customized |
Power of the Voltage Output | 3×100VA | 3×250VA | 3×500VA | 3×1000VA |
Resolution | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range |
Setting Accuracy | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value |
Stability | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) |
Load Regulation from 0-max. Load | < 0.01% | < 0.01% | < 0.01% | < 0.01% |
Distortion Factor | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load |
Harmonics (2nd – 21st) | Free programmable | Free programmable | Free programmable | Free programmable |
Current | ||||
Test Current Output | 3×(1mA – 100A) | 3×(1mA – 100A) | 3×(1mA – 100A) | 3×(1mA – 100A) |
Power of the Current Output | 3×150VA | 3×350VA | 3×750VA | 3×1500VA |
Resolution | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range |
Setting Accuracy | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value |
Stability | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) |
Load Regulation from 0-max. Load | < 0.01% | < 0.01% | < 0.01% | < 0.01% |
Distortion Factor | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load |
Harmonics (2nd – 21st) | Free programmable | Free programmable | Free programmable | Free programmable |
Phase Angle | ||||
Range | 0 -- 360° | 0 -- 360° | 0 -- 360° | 0 -- 360° |
Resolution | 0.01° | 0.01° | 0.01° | 0.01° |
Setting Accuracy | 0.1° | 0.1° | 0.1° | 0.1° |
Frequency | ||||
Range | 45Hz – 65Hz | 45Hz – 65Hz | 45Hz – 65Hz | 45Hz – 65Hz |
Resolution | 0.01Hz | 0.01Hz | 0.01Hz | 0.01Hz |
Voltage Supply | ||||
Voltage Supply | 3×220/380V±10% or customized | 3×220/380V±10% or customized | 3×220/380V±10% or customized | 3×220/380V±10% or customized |
Frequency | 50/60Hz±2Hz | 50/60Hz±2Hz | 50/60Hz±2Hz | 50/60Hz±2Hz |
Operating Conditions | ||||
Ambient Temperature | -10°C -- +40°C | -10°C -- +40°C | -10°C -- +40°C | -10°C -- +40°C |
Relative Humidity | 35-- 85% | 35% -- 85% | 35% -- 85% | 35% -- 85% |
YCS-101-250 | YCS-101-600 | YCS-101-1200 | YCS-101-2500 | |
Voltage Source | ||||
Test voltage output (Phase-Neutral) | 24V – 288V or customized | |||
Power of the voltage output | 100VA | 250VA | 500VA | 1000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | < 0.01% | |||
Distortion factor | < 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Current Source | ||||
Test current output | 1mA – 100A | |||
Power of the current output | 150VA | 350VA | 750VA | 1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | < 0.01% | |||
Distortion factor | < 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Phase angle | ||||
Range | 0 -- 360° | |||
Resolution | 0.01° | |||
Setting accuracy | 0.1° | |||
Frequency | ||||
Range | 45Hz – 65Hz | |||
Resolution | 0.01Hz | |||
Voltage Supply | 220V±10% or 50/60Hz±2Hz or customized | |||
Ambient temperature | -10°C -- +40°C | |||
Relative humidity | 35% -- 90% |