Application Conditions and Requirements | ||||
Environment | Safety | |||
Operation Temperature | Relative Humidity | Altitude | IP Class | Conformity |
-25°C-50°C | 40%-95% | <2500m | 40/54 | IEC |
Items | YC99T-3C | YC99T-5C | |
Output Range | 57.7V, 100V, 220V, 380V, 660V | 57.7V, 100V, 220V, 380V | |
AC Voltage Output | Adjustment Range | (0~120)%RG | |
Adjustment Degree | 0.01%RG, 0.1%RG, 1%RG, 10%RG (optional) | ||
Stability | 0.01%/2min | ||
Distortion | ≤0.2% (Non-capacitive load) | ||
Output Max. Load | 20VA/phase | ||
Measurement Accuracy | 0.05%RG | ||
Output Range | 50mA, 200mA, 1A,5A,16.677A,50A | ||
AC Current Output | Adjustment Range | (0~120)%RG | |
Adjustment Degree | 0.01%RG, 0.1%RG, 1%RG, 10%RG (optional) | ||
Stability | 0.01%/2min | ||
Distortion | ≤0.2% (Non-capacitive load) | ||
Output Max. Load | 60VA (50A range, 120% output) | 90VA (100A range, 120% output) | |
Measurement Accuracy | 0.05%RG | 0.05%RG | |
Stability | 0.01%RG/2min | 0.01%RG/2min | |
Power Output | Active & Reactive Power Measurement Accuracy | 0.05%RG | |
Phase Output | Adjustment arrange | 0°~360° | |
Adjustment Degree | 10°, 1°, 0.1°, 0.01° (optional) | ||
Resolution | 0.01° | ||
Accuracy | 0.05° | ||
Adjustment Range | ‘-1~0~ +1 | ||
Power Factor Output | Measurement resolution | 0.0001 | |
Measurement Accuracy | 0.0005 | ||
Frequency Output | Adjustment Range | 40Hz~70Hz | |
Output Adjustment degree | 1HZ,0.1HZ,0.01Hz,0.001Hz are optional | ||
Resolution | 0.001Hz | ||
Accuracy | 0.002 Hz | ||
Harmonic Set Up | Harmonic Times | 2~63 times | |
Harmonic Content | 0~40% | ||
Harmonic Phase | 0°~359.99° | ||
Harmonic Set Up Error | 2~31 times: ≤±0.1%, 32~63 times: ≤±0.2% | ||
Energy Error Measurement | Active PF≥0.5 | ±0.05%RD | |
Active PF=1 | ±0.1%RD | ||
Reactive PF≥0.5 | ±0.1%RD | ||
Reactive PF=1 | ±0.2%RD | ||
General Specification | Power Supply | AC 220V±15% or 110V±15%, 50Hz-60Hz | |
Weight | 28kg | 48kg |