Add to Cart
Environment | Safety | |||
Operation Temperature | Relative Humidity | Altitude | IP Class | Conformity |
20℃-30℃ | 40%-85% | <2500m | 40 | IEC |
General Specification | Power supply | AC 220V±15% or 110V±15% | ||
Frequency | 50Hz~60Hz | |||
Power consumption | 100VA-1000VA | |||
Size & Weight | 658*440*220(mm),30kg | |||
AC Voltage Output | DC voltage output | |||
Three-phase AC high voltage output | Output range | 30V, 57.7V, 100V, 220V, 380V, 660V | Range | "+75mV,±1V,±10V;30V,100V,300V,600V |
Stability | 0.01%/2min | Stability | 0.005%/2min(1V& above);0.01%/2min( 75mV ) | |
Accuracy | 0.02%RG/0.05%RG | Load capacity | 100mA( short term 150mA , 10V & below );30mA ( 30V & above ) | |
AC low voltage output | Output range | 1V, 10V | Accuracy | 0.02%RG Or 0.05%RG(except +75mV ) |
Stability | 0.02%/2min | 0.1%RG(±75mV ) | ||
Accuracy | 0.1%RG | Ripple content | 0.5%RG | |
AC Current Output | DC current output | |||
Three-phase AC high current output | Output Range | 500mA, 1A, 2A, 5A, 10A, 25A, 30A | Range | ±1mA,+20mA ,±100mA;300mA,1A,5A ,10A15A ,25A |
Stability | 0.01%/2min | Stability | 0.005%/2min | |
Accuracy | 0.02%RG/0.05%RG | Accuracy | 0.02%RG(+1mA/±20mA±100mA)or 0.05%RG(±1mA/±20mA100mA)0.05%RG(300mA/1AV5A/10A/15A/25A); | |
Single-phase AC small current output | Output Range | 100mA | Ripple content | 0.5%RG( 100mA & below );1%RG( 300mA & above ) |
Stability | 0.05%/2min | DC input Voltage Measurement | ||
Distortion | ≤0.2% | Range | ±10V | |
Accuracy | 0.p%RG | Measurement range | 0~125%RG | |
Power measurement accuracy | Active:0.03%RG/0.05%RG Reactive:0.06%RG/0.1%RG | Accuracy | 0.01%RG | |
Phase factor output | Adjustment Range | -1.0000 to +1.0000 | Ripple measurement range | 0~200mVrms |
Resolution | 0.0001 | Resolution | 0.001%RG | |
Accuracy | ±0.0005 | DC input Current Measurement | ||
Frequency Output | Adjustment Range | 40Hz to 70Hz | Range | ±20mA |
Resolution | 0.001Hz | Measurement range | 0~125%RG | |
Accuracy | 0.01%RG | |||
Ripple measurement range | 0~2mAms | |||
Accuracy | ±0.002 Hz | Resolution | 0.001%RG | |
Electrical Energy Error Measurement | ||||
harmonic output | times | 2~63 | Active energy measurement accuracy | 0.05%RD(15V~792V,0.05A~30A,PF0.5);0.1%RD(15V~792V,0.02A~0.05A,PF=1); |
Accuracy of reactive energymeasurement | 0.1%RD(15V~792V,0.05A~30A,PF20.5);0.2%RD(15V~792V,0.02A~0.05A,PF=1); | |||
content | 0~40% | |||
phase | 0°~359.99° | |||