Guangzhou GENY Electric Co., Ltd

Professional in Energy Meter Testing

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Energy Meter Testing Equipment /

6-In-1 DC Energy Meter Testing Equipment Testing Of Single Phase Energy Meter

Contact Now
Guangzhou GENY Electric Co., Ltd
Visit Website
City:guangzhou
Country/Region:china
Contact Person:MrJohn Shen
Contact Now

6-In-1 DC Energy Meter Testing Equipment Testing Of Single Phase Energy Meter

Ask Latest Price
Video Channel
MOQ :1
Price :negotiate rates
Payment Terms :L/C, D/P, T/T, D/A
Supply Ability :2 sets/ 3 months
Delivery Time :6~8weeks
Packaging Details :Plywood cases
Brand Name :GENY
Model Number :YC1891F
Certification :ISO, CE
Place of Origin :CHINA
Appearance :LED light
Current Output Range :0~600A DC current
Voltage Output :0V - 10kV
Standard :IEC 60736
Usage :energy meter calibration, lab research
Support :Ripple test
Storage Temperature :-20-70°C
Outer Casing :aluminum alloy
Frequency Range :45-65Hz
Test Object :ring main unit (RMU)
Output Power :1000VAC
Ac Frequency Range :0.001-5KHz
Accuracy :0.05%
Output Range :0~250A-AC
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

6-In-1 DC Energy Meter Testing Equipment For Testing Of DC Energy Meter

Product description

The YC-9600T6/9100T6/YC-2015Z DC energy meter test instrument is a DC energy meter test instrument that meets the requirements of GB/T 33708-2017, Q/GWD1826-2013, and Q/GDW 1825-2013. It has the following features:

  • It has 6 meter under test positions and can simultaneously test 6 meters of electric energy meters (0~100A) or 3 meters of electric energy meters (0~600A).
  • It can output DC voltage, DC current, and small signal, and realize the addition output of electric energy meter test.
  • It has a voltage accuracy of 0.02% grade, a current accuracy of 0.02% grade, and an energy accuracy of 0.05%.
  • It has a voltage and current output stability of ±(0.01%*RD+0.005%RG)/min, a current stability of ±(0.01%*RD+0.005%RG)/min, and a year drift of less than 100ppm/year.
  • It has a voltage and current ripple output capability of 0~500Hz, a pulse coefficient that allows output greater than 30% of the pulse, a ripple phase of less than 0.1 degree, and a ripple accuracy of 5%.
  • It has a working power of AC 220V ±5% 50Hz, a relative humidity of ≤85%, and no corrosive gas.
  • It has a size of 600mm×600mm×1610mm (width×depth×height) and 1552mm×540mm×1505mm (length×width×height).

Technical parameters

The technical data of YC-9600T6/9100T6/YC-2015Z DC energy meter test instrument are as follows:

  • Voltage accuracy: 0.02% grade
  • Current accuracy: 0.02% grade
  • Energy accuracy: 0.05%
  • Voltage and current output stability: ±(0.01%*RD+0.005%RG)/min
  • Current stability: ±(0.01%*RD+0.005%RG)/min
  • Year drift: less than 100ppm/year
  • Voltage and current ripple output capability: Ripple frequency: 0~500Hz Pulse coefficient: allows output greater than 30% of the pulse Ripple phase: The phase error of voltage and current ripple is less than 0.1 degree Ripple accuracy: 5%
  • Other indicators: Working power: AC 220V ±5% 50Hz Relative humidity: ≤85% No corrosive gas
  • Size: Cabinet: 600mm×600mm×1610mm (width×depth×height) Table: 1552mm×540mm×1505mm (length×width×height)

DC engery test bench
Meter under positions 1~ 6
six-way dc voltage output
Quantity limit 0 ~ 1000V (MAX :1150V )
gear 60V ,500V ,1000V
accuracy 0.02% class
maximumoutput 30W

One-way DC current output

Quantity limit 600A

gear

1mA ,5mA ,20 mA ,50 mA ,200 mA ,1 A ,5 A ,

10 A , 20 A ,60 A ,100 A ,500 A

accuracy 0.02% class
capability port voltage is greater than 3V

six-way indirect current

output

Quantity limit 0~5V
gear Supports 2 .5mV, 20 mV, 100 mV (75 mV rated), 1V, 5V, and five gears

accuracy

2.5 mV range: ± (0 .05% * RD + 7 μ V)
20 mV range: ± (0 .02% * RD + 10 μ V);
100 mV range: ± (0 .02% * RD + 10 μ V);
100mV … 5V range: ± (0 .02% * RD + 10 μ V)

capability

Output of the U <= 100mV is 1mA;
100mv <u <= 5V with the output 10mA
Electric energyaccuracy
Electric energyaccuracy 0.05%

voltage and current output

stability

voltage stability ±(0 . 01% * RD +0 .005%RG ) /min
current stability ±(0 . 01% * RD +0 .005%RG ) /min
year drift Less than 100ppm / year

voltage andcurrent ripple

output capacity

ripple frequency 0 ~ 500 Hz
pulse coefficient per low output greater than30%
ripple phase

The voltage and current ripple phase error is less

than 0.1 degrees

ripple accuracy 5%
other indicators
working power supply AC 220V ±5% 50Hz
relative humidity 85%

6-In-1 DC Energy Meter Testing Equipment Testing Of Single Phase Energy Meter

Inquiry Cart 0