Guangzhou GENY Electric Co., Ltd

Professional in Energy Meter Testing

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Stationary Power Source /

Accuracy 0.02 Energy Stationary Power Source Max 21 Times Harmonic Free

Contact Now
Guangzhou GENY Electric Co., Ltd
Visit Website
City:guangzhou
Country/Region:china
Contact Person:MrJohn Shen
Contact Now

Accuracy 0.02 Energy Stationary Power Source Max 21 Times Harmonic Free

Ask Latest Price
Video Channel
Brand Name :GENY
Model Number :YCS-103
Certification :ISO, CE
Place of Origin :China
MOQ :1
Price :negotiate rates
Payment Terms :T/T,L/C,D/P,T/T
Supply Ability :5 sets / 1 months
Delivery Time :6~8weeks
Packaging Details :Plywood cases
Test voltage output :3×(24V – 288V) or customized
Power of the voltage output :3×100VA/3×250VA/3×500VA/3×1000VA
Test current output :3×(1mA – 100A)
Phase angle range :0 -- 360°
Relative humidity :35% -- 85%
Ambient temperature :-10°C -- +40°C
Voltage Supply :3×220/380V±10% or customized 50/60Hz±2Hz
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Max 21 Times Harmonic Free Programmable Three Phase Energy Stationary Power Systems with Accuracy Class 0.02


Technical Specifications:


Max 21 Times Harmonic Free High Precision Three Phase Energy Stationary Power Source


Parameter YCS-103-250 YCS-103-600 YCS-103-1200 YCS-103-2500
Voltage



Test Voltage Output (Phase-Neutral) 3×(24V – 288V) or customized 3×(24V – 288V) or customized 3×(24V – 288V) or customized 3×(24V – 288V) or customized
Power of the Voltage Output 3×100VA 3×250VA 3×500VA 3×1000VA
Resolution Better than 0.01% of full scale value of range Better than 0.01% of full scale value of range Better than 0.01% of full scale value of range Better than 0.01% of full scale value of range
Setting Accuracy Better than 0.05% at the final range value Better than 0.05% at the final range value Better than 0.05% at the final range value Better than 0.05% at the final range value
Stability Better than 0.005%/h (integration time 150 s) Better than 0.005%/h (integration time 150 s) Better than 0.005%/h (integration time 150 s) Better than 0.005%/h (integration time 150 s)
Load Regulation from 0-max. Load < 0.01% < 0.01% < 0.01% < 0.01%
Distortion Factor < 0.3% for linear resistance load < 0.3% for linear resistance load < 0.3% for linear resistance load < 0.3% for linear resistance load
Harmonics (2nd – 21st) Free programmable Free programmable Free programmable Free programmable
Current



Test Current Output 3×(1mA – 100A) 3×(1mA – 100A) 3×(1mA – 100A) 3×(1mA – 100A)
Power of the Current Output 3×150VA 3×350VA 3×750VA 3×1500VA
Resolution Better than 0.01% of full scale value of range Better than 0.01% of full scale value of range Better than 0.01% of full scale value of range Better than 0.01% of full scale value of range
Setting Accuracy Better than 0.05% at the final range value Better than 0.05% at the final range value Better than 0.05% at the final range value Better than 0.05% at the final range value
Stability Better than 0.005%/h (integration time 150 s) Better than 0.005%/h (integration time 150 s) Better than 0.005%/h (integration time 150 s) Better than 0.005%/h (integration time 150 s)
Load Regulation from 0-max. Load < 0.01% < 0.01% < 0.01% < 0.01%
Distortion Factor < 0.3% for linear resistance load < 0.3% for linear resistance load < 0.3% for linear resistance load < 0.3% for linear resistance load
Harmonics (2nd – 21st) Free programmable Free programmable Free programmable Free programmable
Phase Angle



Range 0 -- 360° 0 -- 360° 0 -- 360° 0 -- 360°
Resolution 0.01° 0.01° 0.01° 0.01°
Setting Accuracy 0.1° 0.1° 0.1° 0.1°
Frequency



Range 45Hz – 65Hz 45Hz – 65Hz 45Hz – 65Hz 45Hz – 65Hz
Resolution 0.01Hz 0.01Hz 0.01Hz 0.01Hz
Voltage Supply



Voltage Supply 3×220/380V±10% or customized 3×220/380V±10% or customized 3×220/380V±10% or customized 3×220/380V±10% or customized
Frequency 50/60Hz±2Hz 50/60Hz±2Hz 50/60Hz±2Hz 50/60Hz±2Hz
Operating Conditions



Ambient Temperature -10°C -- +40°C -10°C -- +40°C -10°C -- +40°C -10°C -- +40°C
Relative Humidity 35-- 85% 35% -- 85% 35% -- 85% 35% -- 85%


Description:

  • Constructed from aluminum alloy materials, this device boasts a combination of lightweight properties and robustness, effectively preventing corrosion while ensuring high accuracy and stability in output.
  • Equipped with an optional keyboard, facilitating manual operation as needed.
  • Capable of outputting from the 2nd to the 21st harmonic, with programmable amplitudes and degrees.
  • Easily operable via PC control software suite, streamlining operation processes.
  • Features an RS232 interface, enabling automatic operation and integration with external systems.
  • Incorporates protective measures against overload, short voltage circuits, and open current circuits, ensuring safety and reliability during operation.

Applications:

  • State metrology offices
  • National utilities
  • Major energy meter manufacturers

Primary Competitive Advantages:

  • High power output (max voltage power: 1000VA, current power: 1500VA)
  • High quality product
  • Extremely high power stability
  • Distortion factor less than 0.3% for linear resistive load

Accuracy 0.02 Energy Stationary Power Source Max 21 Times Harmonic Free

Accuracy 0.02 Energy Stationary Power Source Max 21 Times Harmonic Free

Accuracy 0.02 Energy Stationary Power Source Max 21 Times Harmonic Free

Accuracy 0.02 Energy Stationary Power Source Max 21 Times Harmonic Free

*If you want to know more please check our official website:http://www.genymetertestequipment.com/

Inquiry Cart 0