Add to Cart
1.Exceptional Precision and Reliability:
Our device stands out for its meticulous precision and steadfast reliability, ensuring dependable performance that aligns with the high-quality standards of global markets.
2.Seamless Integration with RS232 Interface:
The inclusion of an RS232 interface facilitates a smooth and efficient connection with a variety of computer systems, providing a level of automation that is universally appreciated.
3.User-Centric Manual Control with Optional Keyboard:
An optional keyboard is available for those seeking the flexibility of manual control, offering a direct and user-friendly interface that enhances the operational experience.
4.Customizable Harmonic Output for Versatile Applications:
The device's ability to program output from the 2nd to the 21st harmonic allows for a tailored approach to meet diverse regulatory and operational requirements across industries.
5.Robust and Portable Aluminum Alloy Design:
Crafted with a durable aluminum alloy, the device combines robustness with portability, ensuring longevity and ease of use in various settings.
6.Intuitive PC Control Software for Enhanced Productivity:
The device is complemented by PC control software that is straightforward and intuitive, designed to boost productivity and streamline workflow processes.
7.Comprehensive Safety Features for Peace of Mind:
Equipped with comprehensive safety features, including protection against overloads, short circuits, and open circuits, the device ensures a secure operation that instills confidence in its users.
YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 | |
Voltage | ||||
Test voltage output (Phase-Neutral) | 3×(24V – 288V) or customized | |||
Power of the voltage output | 3×100VA | 3×250VA | 3×500VA | 3×1000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | < 0.01% | |||
Distortion factor | < 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Current | ||||
Test current output | 3×(1mA – 100A) | |||
Power of the current output | 3×150VA | 3×350VA | 3×750VA | 3×1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | < 0.01% | |||
Distortion factor | < 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Phase angle | ||||
Range | 0 -- 360° | |||
Resolution | 0.01° | |||
Setting accuracy | 0.1° | |||
Frequency | ||||
Range | 45Hz – 65Hz | |||
Resolution | 0.01Hz | |||
Voltage Supply | 3×220/380V±10% or customized 50/60Hz±2Hz | |||
Ambient temperature | -10°C -- +40°C | |||
Relative humidity | 35% -- 85% |
1. Nation-level utility companies
2. Governmental bureaus of metrology
3. Big energy meter manufacturers
1. High quality product
2. High power output (max. voltage power: 1000VA, current power: 1500VA)
3. Extremely high power stability
4. Distortion factor less than 0.3% for linear resistance load