Add to Cart
YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 | |
Voltage | ||||
Test voltage output (Phase-Neutral) | 3×(24V – 288V) or customized | |||
Power of the voltage output | 3×100VA | 3×250VA | 3×500VA | 3×1000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | < 0.01% | |||
Distortion factor | < 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Current | ||||
Test current output | 3×(1mA – 100A) | |||
Power of the current output | 3×150VA | 3×350VA | 3×750VA | 3×1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | < 0.01% | |||
Distortion factor | < 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Phase angle | ||||
Range | 0 -- 360° | |||
Resolution | 0.01° | |||
Setting accuracy | 0.1° | |||
Frequency | ||||
Range | 45Hz – 65Hz | |||
Resolution | 0.01Hz | |||
Voltage Supply | 3×220/380V±10% or customized 50/60Hz±2Hz | |||
Ambient temperature | -10°C -- +40°C | |||
Relative humidity | 35% -- 85% |
1. Nation-level utility companies
2. Governmental bureaus of metrology
3. Big energy meter manufacturers
1. High quality product
2. High power output (max. voltage power: 1000VA, current power: 1500VA)
3. Extremely high power stability
4. Distortion factor less than 0.3% for linear resistance load