Guangzhou GENY Electric Co., Ltd

Professional in Energy Meter Testing

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Stationary Meter Test Bench /

Accuracy 0.02% Energy Meter Test Bench 3 Phase With ICTs For Smart Meter

Contact Now
Guangzhou GENY Electric Co., Ltd
Visit Website
City:guangzhou
Country/Region:china
Contact Person:MrJohn Shen
Contact Now

Accuracy 0.02% Energy Meter Test Bench 3 Phase With ICTs For Smart Meter

Ask Latest Price
Video Channel
Brand Name :GENY
Model Number :YC1893D
Certification :ISO, CE
Place of Origin :China
MOQ :1
Price :negotiate rates
Payment Terms :T/T, L/C, D/P, T/T
Supply Ability :5 sets / 1 months
Delivery Time :6~8weeks
Packaging Details :Plywood cases
Accuracy :0.02
Standard Meter :SZ03A-K8
Power capacity :> 6 kVA
Meter Position :1~3
Structure :All-in-one
Usage :Energy Meter Calibration, Lab Research
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Accuracy Class 0.02% Three-Phase Electronic Energy Meter Test System with ICTs for Smart Meter

Description:

The YC1893D meter test system is a full-automatic test system for testing and calibration of both single-phase and three-phase electric energy meters, which composes of:

  • Three-phase Power source
  • Three-phase Reference standard meter
  • Meter suspension test rack
  • Tariffs control system (fixed voltages, optical port reader, ripple control box)
  • Other necessary parts
  • PC and software controlling the whole system

The YC1893D meter test system is fully compliant with the IEC 60736 standard and is suitable for testing meters according to the following standards:

  • IEC 62052-11 and IEC 62053-11, -21, -22, -23, -24
  • IEC 62056
  • EN 50470-1, EN 50470-2, EN-50470-3
  • IEC 61010

Features and Functions

  • The meter test system can measure mechanical meters, electronic mechanical meters and electronic meter by the way of automatic, semi-automatic or manual operation.
  • Aluminium alloy material, light and strong and corrosion resistant.
  • Automatic positioning rotor mark of disc of mechanical meter, with more efficiency.
  • The swing together of the scanning heads simplifies the control.
  • Fully automatic completion of the following tests:
    • Accuracy test in all four quadrants (active, reactive and apparent energy)
    • Creep test (No-load test)
    • Starting current test
    • Dial test (Register test)
    • Meter constant test
    • Influence quantity test (voltage, frequency, harmonic distortion, etc.)
    • Calibration of reference standard meter having lower accuracy than the employed reference standard
    • Pre-warming
    • Dips and Interruptions
    • Testing single-phase meters under tampered conditions
  • Measuring different constants of meters synchronously.
  • With the protection function of overload, short voltage circuit and open current circuit.

Technical specification for 1~3 position meter test system

The test bench is multiple positions up to 3 meters, 0.02% of accuracy class Three-phase Meter Test System with ICTs, with multiple serial port communication system for parallel communication for testing of smart meters.

Power Supply

Voltage 3×240±15%
Frequency 50 Hz ±15%
Power capacity > 6 kVA
Power efficient(at full load) ≥85%
Ambient temperature -10 °C -- +40 °C
Relative humidity 35% -- 85%

Power Source

Voltage
Test voltage output (Phase-Neutral) 3×(24 V – 480 V) or 600 V F-F customized
Power of the voltage output 3×100VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.02% at the final range value
Stability Better than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load < 0.01%
Distortion factor < 0.3% for linear resistance load
Harmonics 2nd – 21st free programmable
Current
Test current output 0.3 mA – 120 A
Power of the current output 3×150VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.02% at the final range value
Stability Better than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load < 0.01%
Distortion factor < 0.3% for linear resistance load
Harmonics 2nd – 21st free programmable
Phase angle
Range 0 -- 360°
Resolution 0.01°
Setting accuracy 0.1°
Frequency
Range 45 Hz – 65 Hz
Resolution 0.01 Hz
Accuracy 0.02% Energy Meter Test Bench 3 Phase With ICTs For Smart Meter